We use optional Google Analytics to understand site use. It starts only if you accept analytics. You can reject it or change your choice at any time. Privacy Policy

SEER POWER

Product Specifications

Download engine specificationsMore engine brands for this power range · XLSX
ModelPrime Power (kW / kVA)Standby Power (kW / kVA)EngineEngine ModelAlternatorFrequency (Hz)Voltage (V)Open Type (L × W × H) (mm)Open Type Weight (kg)Silent Type (L × W × H) (mm)Silent Type Weight (kg)
SP-1600WC1600 / 20001760 / 2200Weichai16M33D1980E310Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 48012192 × 2438 × 350017050
SP-1650WC1650 / 2062.51815 / 2269Weichai20M33D2020E310Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 48012192 × 2438 × 350017000
SP-1800WC11800 / 22502000 / 2500Weichai20M33D2210E310Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 48012192 × 2438 × 350017500
SP-1800WC1800 / 22502000 / 2500Weichai12M55D2210E310Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 4806400 × 2430 × 28782120012192 × 3000 × 300024700
SP-2000WC2000 / 25002200 / 2750Weichai12M55D2450E310Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 4806400 × 2430 × 28782120012192 × 3000 × 300025100
SP-2200WC2200 / 27502420 / 3025Weichai12M55D2700E310Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 4806400 × 2430 × 28782220012192 × 3000 × 300026500
SP-2250WC2250 / 2812.52500 / 3125Weichai16M55D2750E310Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 48015000 × 3500 × 460034000
SP-2400WC2400 / 30002640 / 3300Weichai16M55D2900E310Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 4808200 × 2800 × 37002950015000 × 3500 × 460034500
SP-2600WC2600 / 32502860 / 3575Weichai16M55D3300E310Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 4808200 × 2800 × 37002950015000 × 3500 × 460035000
SP-3000WC3000 / 37503300 / 4125Weichai16M55D3600E310Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 48015000 × 3500 × 460035500

Weichai engines and Leroy-Somer or SEER POWER alternators are shown as examples in this table. Other engine and alternator brands are available. Frequency, voltage and component selection can be customized for each project. Blank Open Type fields indicate that data is not available for the listed model.

Swipe horizontally to view all specifications.

GENERATOR SYSTEM

Standard Configuration

CURRENT SELECTIONDiesel Engine / Cummins

SYSTEM SELECTOR
01 OF 07
Open-frame generator with a small output circuit breaker and a SEER container behind it
ENGINE BRAND
Selected Cummins

Brand Overview

Cummins G-Drive engines are purpose-built for generator applications. The range includes engine families for standby and prime-power duties, with the selected series determining the cooling, fuel system and controls.

G-Drive integration

Cummins describes model-specific cooling, air-cleaner and service components within its G-Drive engine packages.

Project selection

The final engine rating, control interface and installation details are checked against the project load and destination.

Product Features

  • Proven reliability & durability
  • High power with strong torque
  • Optimized fuel efficiency
  • Global service network

Optional Configurations

SEER POWER red sound-attenuated generator enclosure, slight right-side view
Sound-attenuated enclosure

Custom Sound-Attenuated Enclosure

An upgrade to the standard enclosure, with acoustic treatment, airflow, access or finish adapted to the confirmed site brief.

SEER POWER red twin-axle trailer-mounted generator

Trailer-Mounted

Mobile power package for temporary projects and changing job sites.

Illustrative automatic transfer switch cabinet

Parallel / ATS

Scalable power with synchronization and automatic transfer control.

White SEER generator container with black rooftop cooling equipment and pipework
Containerized diesel generator enclosure

Containerized

Containerized enclosure for weather protection and site installation.

Illustrative alternator terminal box for voltage configuration

Voltage Options

Voltage configurations tailored to distribution and application requirements.

Main Applications for 1,875+ kVA Industrial Diesel Generators

Projects above this level are usually engineered as project-specific or multi-unit systems. Capacity, redundancy and switching must be confirmed from the full load study.

Modern commercial and retail buildings
Commercial and retail

Project-specific power systems for very large commercial districts or central utility plants.

Multi-unit commercial power systemMulti-unit commercial power system

Typical applications for this power range, subject to the confirmed load and project requirements.

Typical application fitTypical application fit

Integrated commercial developments and campus-wide central services.

Selection focusSelection focus

Define total capacity, N+1 intent, distribution voltage, load shedding and phasing.

Total capacityTotal capacity
N+1 intentN+1 intent
Distribution voltageDistribution voltage
PhasingPhasing

FREQUENTLY ASKED QUESTIONS

TESTED. TRUSTED. DELIVERED.

Factory testingDocumented inspection and test procedures

Load bank testingTest scope matched to the project

Coordinated deliveryPackaging and documentation confirmed before shipment

24/7 Technical SupportRemote assistance for commissioning and operation