SEER POWER

DIESEL POWER. BUILT FOR RELIABILITY.

375-750 kVA
Industrial Diesel
Generators

Industrial diesel generator sets engineered for dependable performance, fuel efficiency and demanding operating conditions.

  • 375–750 kVA / 300–600 kW prime power range
  • 50 / 60 Hz configurations available
  • Open, sound-attenuated and containerized options
  • Multiple engine, alternator and voltage choices
VIEW SPECIFICATIONS

WHY SEER POWER

Built for
Real-World Power

01 Application-Matched Engineering
02 Verified Factory Testing
03 Coordinated Global Delivery
04 24/7 Technical Support

Product Specifications

Download specifications5 engine brand XLSX files
ModelPrime Power (kW / kVA)Standby Power (kW / kVA)EngineEngine ModelAlternatorFrequency (Hz)Voltage (V)Open Type (L × W × H) (mm)Open Type Weight (kg)Silent Type (L × W × H) (mm)Silent Type Weight (kg)
SP-320WC320 / 400350 / 437.5WeichaiWP13D385E200Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 4803140 × 1295 × 17902925(3250 + 650) × 1300 × 21003650
SP-328WC328 / 410360 / 450WeichaiWP13D405E200Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 480(3250 + 650) × 1300 × 21003680
SP-350WC350 / 437.5385 / 481.3WeichaiWP13D440E310Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 4803140 × 1295 × 17902925(3250 + 650) × 1300 × 21003690
SP-400WC400 / 500440 / 550WeichaiWP13D490E310Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 4803140 × 1295 × 17902975(3250 + 650) × 1300 × 21003740
SP-460WC460 / 575506 / 632.5Weichai6M33D572E200Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 4803750 × 1600 × 20754930(3900 + 600) × 2000 × 24005800
SP-520WC520 / 650572 / 715Weichai6M33D633E200Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 4803810 × 1600 × 20754980(3900 + 600) × 2000 × 24005800
SP-540WC540 / 675600 / 750Weichai6M33D670E200Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 4803850 × 1830 × 22604980(3900 + 600) × 2000 × 24005800
SP-600WC600 / 750660 / 825Weichai6M33D725E310Leroy-Somer / SEER POWER50 / 60220 / 230 / 380 / 400 / 415 / 440 / 4803850 × 1600 × 21405900(3980 + 820) × 1800 × 24256200

Weichai engines and Leroy-Somer or SEER POWER alternators are shown as examples in this table. Other engine and alternator brands are available. Frequency, voltage and component selection can be customized for each project. Blank Open Type fields indicate that data is not available for the listed model.

Swipe horizontally to view all specifications.

GENERATOR SYSTEM

Standard Configuration

CURRENT SELECTIONDiesel Engine / Cummins

SYSTEM SELECTOR
01 OF 07
1,250–1,875 kVA open diesel generator set, three-quarter view
ENGINE BRAND
Selected Cummins

Brand Overview

Cummins G-Drive engines are purpose-built for generator applications. The range includes engine families for standby and prime-power duties, with the selected series determining the cooling, fuel system and controls.

G-Drive integration

Cummins describes model-specific cooling, air-cleaner and service components within its G-Drive engine packages.

Project selection

The final engine rating, control interface and installation details are checked against the project load and destination.

Product Features

  • Proven reliability & durability
  • High power with strong torque
  • Optimized fuel efficiency
  • Global service network

Optional Configurations

White sound-attenuated diesel generator enclosure with service doors

Custom Sound-Attenuated Enclosure

An upgrade to the standard enclosure, with acoustic treatment, airflow, access or finish adapted to the confirmed site brief.

Trailer-mounted diesel generator set with wheels, tow bar and support leg

Trailer-Mounted

Mobile power package for temporary projects and changing job sites.

Illustrative automatic transfer switch cabinet beside a diesel generator

Parallel / ATS

Scalable power with synchronization and automatic transfer control.

Containerized generator enclosure
Containerized diesel generator enclosure

Containerized

Containerized enclosure for weather protection and site installation.

Illustrative generator output switchgear cabinet beside a diesel generator

Voltage Options

Voltage configurations tailored to distribution and application requirements.

Main Applications for 375–750 kVA Industrial Diesel Generators

Applications at this level usually combine larger motors, more building services or wider site distribution. Load steps and system coordination become central.

Sound-attenuated diesel generator set outside a modern retail building
Commercial and retailCommercial and retail

Standby power for shopping centers, distribution buildings and larger commercial premises.

Large commercial standby setLarge commercial standby set

Typical applications for this power range, subject to the confirmed load and project requirements.

Typical application fitTypical application fit

Malls, distribution centers and commercial sites with several essential systems.

Selection focusSelection focus

Model load steps across HVAC, refrigeration, lifts and life-safety services.

Load stepsLoad steps
HVACHVAC
Life safetyLife safety
DistributionDistribution

FREQUENTLY ASKED QUESTIONS

TESTED. TRUSTED. DELIVERED.

Factory testingDocumented inspection and test procedures

Load bank testingTest scope matched to the project

Coordinated deliveryPackaging and documentation confirmed before shipment

24/7 Technical SupportRemote assistance for commissioning and operation

Scroll to Top